PDS813 Pulp and Paper Pressure Transmitter
Features a flush-diaphragm process connection for pressure measurement in high-viscosity and clog-prone media such as pulp. Facilitates easy cleaning and maintains consistent measurement performance.
Technical data
| Best measurement accuracy: | ±0.025%FS | Measuring range: Gauge: | -0.1 to 6.3 MPa |
| Maximum turndown ratio: | 30:1 | Process temperature: | -40°C to +120°C |
| Pressure rating: | Maximum overload pressure: 10 MPa | Communication protocols: | HART 7, PROFIBUS-PA 3.02, FOUNDATION Fieldbus 6.1.1, Ethernet-APL, AutBus |
| Output signal: | 4–20 mA DC with HART; digital fieldbus signals | Power supply: | 4–20 mA: 10.5 to 45 VDC; HART communication: 15.8 to 45 VDC; PA/FF: 9 to 32 VDC; Ethernet-APL: 9.6 to 15 VDC |
| Long-term stability: | ≤±0.1%FS over 10 years | Body temperature effect at 1:1 turndown: | ≤±0.07%FS/28°C |
| Response time: | ≤90 ms | Ambient temperature: | -40°C to +85°C |
| Ingress protection: | IP66/IP67 | Damping setting: | 0 to 100 s |
| Electrical entries: | M20×1.5; 1/2 NPT | HART loop load: | 230 to 500 Ω |
| Power supply effect: | ≤0.005% of calibrated span/V |
Features & Benefits
Flush Diaphragm, Reduced Buildup
Flush diaphragm designed to minimize buildup of pulp and high-viscosity media.
Specialized Connections, Reduced Clogging
Specialized process connection helps reduce the risk of clogging.
Front-Mounted Sensor, Easy Maintenance
Front-mounted sensing element facilitates cleaning and maintenance.
High Accuracy, Long-Term Stability
High measurement accuracy with long-term stability supports uninterrupted production.
Smart Diagnostics, Flexible Communication
Supports intelligent diagnostics and multiple communication configurations.